MULTI-FUNCTION METER
for BATCH CONTROL,
RATE INDICATION and
TOTALIZATION
P5000
Frequency Ratemeter
Frequency Ratio
Up or Down Totalizer/ Batch Controller
RS-232C and HI, LO and GO Open-Collector
Outputs Standard
Analog Output for Rate or Total (Optional)
Shown with FP7000 Series paddlewheel flow sensor - sold separately.
|
|
The P5000 microprocessor-based, 6-digit, 1/8 DIN panel instrument
can be configured by front-panel keys or by a personal computer as a frequency
meter/ tachometer, frequency-ratio meter, period/ period-average meter,
time-interval/time-interval-average meter, reset stopwatch, and cumulative
timer or totalizer/1-stage batch controller. However, the P5000 display
cannot toggle between rate and total. Two signal inputs can be used to
provide frequency ratio or time-interval measurements.
Five Operating Modes
In the frequency meter, the minimum display update rate is equal to 1
period of the frequency input. Thus, very low frequency measurements are
displayed and updated faster than most conventional frequency meters.
Only two sensors are required to measure the rate of a moving object.
The P5000 can be set up as frequency-ratio meter, ideal for monitoring
flow ratios.
The P5000 can be set up as an up or down totalizer/1-stage batch controller
at rates up to 7 MHz. The display capacity is û99,999 to 999,999 counts
with exponential format up to 9.99 E9. Upon ac power loss, the latest
reading is automatically saved in non-volatile RAM and is restored upon
return of power.
SPECIFICATIONS
TTL INPUT
Speed and Protection Levels (jumper selectable): 7 MHz, 0-5 V;
100 kHz, -20 to +25 V; 3 kHz, -20 to +25 V
Isolated Input Sensitivity (square-wave input): ▒10 mV, 0 to 1
kHz; ▒25 mV, 0 to 1 kHz; ▒50 mV at 100 kHz Requires PGA1
NPN or PNP Open-Collector Sensor Excitation Output: 12.4 V at 20
mA
COMMON
SPECIFICATIONS (All Input Types)
Number of Inputs: 1 or 2 (2 inputs for frequency ratio and time
interval only)
Update Rate: 60 msec to 99.99 sec, field programmable
OPERATION MODES
Frequency/Tachometer Modeû Frequency Range: 10-6 Hz to 7 MHz
Accuracy at 25░C (square wave): ▒0.0002% (+2 ppm)
Totalizer DisplayûOffset (preset): û99,999 to 999,999
ISOLATED ANALOG INPUT
Accuracy: better than 99.9%
Non-Linearity: 0.05% FS
Isolation: 350 Vdc between output and input
Power: 230 Vac, 10-32 Vdc
AC Frequency: 49-440 Hz
Power Consumption, Typical: 3 W
Battery Backup: user-supplied 6-12 Vdc, 60 mA to maintain operation,
400 mA with display
Dimensions: 1.9" H x 3.8" W x 5.9" D (48 x 96 x 150 mm); 1.8" x
3.6" (45 x 92 mm ) cutout
ON/OFF CONTROL & ALARM OUTPUTS
Standard: three open-collector transistors, rated 150 mA sink,
30V
Optional:
two form C relays rated 8 A, 30 Vdc, or 240 Vac, resistive load (for rate
alarm or batch control)
Analog Output Optional: isolated, scalable, internally powered
and field selectable for 0-10 V, 4-20 mA, or 0-20 mA. Rangeable over 4
left most or right most digits, suitable for rate or total display.
Min. Impedance for 10 V: 500ohm
Max. External Impedance for 20 mA: 600ohm
Input
Options
æ0Æ = Standard input, dual-channel input board, non-isolated TTL/5
V CMOS-level, frequency range of 10-6 to 7 MHz. Default calibration:
0 to 10 kHz = 0 to 10000.0.
æ1Æ = Isolated single-channel input board with sensor excitation,
protected for signals up to 260 Vac. (P6A1). Default calibration:
0 to 10 kHz = 0 to 10000.0.
æ2Æ = Non-isolated dual-channel input board with sensor excitation.
Protected for input signals up to 260 Vac RMS. (P6A2). Default calibration:
0 to 10 kHz = 0 to 10000.0
æ3Æ = Non-isolated single-channel input board with sensor excitation.
Protected for input signals up to 60 Vac RMS. (P6A3). Default calibration:
0 to 10 kHz = 0 to 10000.0
æ4Æ = Isolated analog-to-frequency single-channel input with 24
Vdc, 0-1 mA, 4-20 mA dc, 1-5 Vdc, and 0-10 Vdc (P6A5).
To
Order (* Complete Model No.) Prices
Shown in U.S. Dollars
P5
|
( * )
|
( * )
|
( * )
|
Description
|
Price
|
|
|
|
|
Power
|
|
|
0
|
|
|
115
Vac power |
$380
|
|
1
|
|
|
230
Vac power |
$380
|
|
4
|
|
|
9
to 32 Vdc power |
$460
|
|
|
|
|
Output
Option |
|
|
|
0
|
|
None |
N/C
|
|
|
1
|
|
Isolated BCD |
$110
|
|
|
2
|
|
Two
8 A form æCÆ relays |
$80
|
|
|
3
|
|
Analog
Output |
$155
|
|
|
|
|
Input
Configuration |
|
|
|
|
0
|
TTL/5VCMOS |
N/C
|
|
|
|
1
|
Isolated
single channel |
$95
|
|
|
|
2
|
Isolated
dual channel |
$110
|
|
|
|
3
|
Non-isolated
single channel |
$65
|
|
|
|
4
|
Analog
to frequency |
$135
|
Ordering Example:
P5021= 115 Vac
power, two relays,
and isolated single
channel input, $380
+ 80 + 95 = $555.
|